Explosion-proof combustible and toxic gas detection system analyzer
Double-gas detection system
Appling for pipage
Continuous sucking leak gas in hot&humid temp, high pressure highland conditon
E-6000/D gas detection system analyzer
A newest launched gas analyzer, a effective extension for the diffusing gas detection, apply analyzer technque of gas sampling, a analyzer used for gas concentration of target ambient, detecting the gas for canning, pipeline and down hole conditions that the fixed gas detector doesn’t work or can’t installment.
Its working pronciple is that the gas analyzer extracts the gas of target areas and send back to analyzer, and achieve the aim of detecting the target gas concentration.
Technical parameters
Signal output | 4-20mA; RS485 | sensitibity drift | less than2%FC/month |
Working voltage | AC220V 50HZ | display | 3+2 LED/ 3-color indication |
power dissipation | less than5W (non heat accompany) | transmission cable | 4-core water-proof screening cable |
Alarm setting | 7% vol (O2); 10ppm( H2S) | Max output distance | no more than 2km |
Relay output | 5A@220V/ 5A@24V DC | Explosion-proof grade | ExdIICT6 |
Detection gases | O2 or H2S | Weight | 80kg |
Detection range | 0-30%vol, 0-100ppm | Heat accompany working woltage | AC220V 50HZ |
Sensor type | Electrochemistry sensor | Heat accompany power dissipation | less than 200W |
Lifetime of analyzer | more than 2 years | Sampling connecting | DN10 flg |
lifetime of air pump | more than 2 years | Sampling pipeline | Diameter 6 stainless steel |
Lifetime of sensor | more than1 year | Operation press | entrance :0.1-0.4Mpa airvent:+/-7kpa |
Applying location | Zone I of hazardous location | Size of analyzer | 900X1100X220 Outdoor usage |
respond time | T90 NO MORE THAN 30s ( increasing 5M of sampling tube, the T90 added 20s) | Zero drift | less than 2%FC/month |
Detection precision | +/-1% | Ambient condicion | Temperature (-40~+70)°C RH:(10~95)%RH Atmosphere press(86~106)kpa |